GENERAL CATALOGUE API

Pressure boosters

Charge features

Ratio: 2:1

Type: MLTR2A09

Type: MLTR2B09

Type: MLTR3A09 MLTP3A09

60

400

12 11 10

50

300

9 8 7 6 5 4 3 2 1 0 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0

40

30

200

20

100

Charging time* t (s)

Charging time* t (s)

Charging time* t (s)

10

0 1,0 1,2 1,4 1,6 1,8 2,0

0 1,0 2,0 3,0 2,0

Pressure increase ratio P 2 /P 1

Pressure increase ratio P 2 /P 1

Pressure increase ratio P 2 /P 1

*Note: for 10 L Required time to charge pressure in the air- reservoir from 10 to 15 bar at 5 bar supply pressure:

*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:

*Note: for 10 L Required time to charge pressure in the air-reservoir from 7 bar to 9,5 bar at 5 bar supply pressure:

P 2 __ P 1

7 __ 5 = = 1,4

P 2 __ P 1

9,5 ____ 5 = = 1,9

P 2 __ P 1

10 __ 5 = = 2,0

P 2 __ P 1

15 ____ 5 = = 3,0

P 2 __ P 1

8 __ 5 = = 1,6

P 2 __ P 1

10 ____ 5 = = 2,0

With pressure increase ratio from 2,0 to 3,0, charge time of 147 – 58 = 89 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:

With pressure increase ratio from 1,6 to 2,0, charge time of 11,5 – 3,8 = 7,7 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:

With pressure increase ratio from 1,4 to 1,9, charge time of 23 – 6 = 17 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:

10 __ 10

10 __ 10

100 __ 10

V __ 10

V __ 10

V __ 10

T = t x

= 17 x

= 17 s

T = t x

= 89 x

= 89 s

T = t x

= 7,7 x

= 17 s

Type: MLTR4A09 MLTP4A09

Type: MLTR4A16

5

5

4

4

3

3

2

2

1 Charging time* t (s)

1 Charging time* t (s)

0 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0

0

1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0

Pressure increase ratio P 2 /P 1

Pressure increase ratio P 2 /P 1

*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:

*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:

4 - ACCESSORIES

P 2 __ P 1

8 __ 5 = = 1,6

P 2 __ P 1

10 ____ 5 = = 2,0

P 2 __ P 1

8 __ 5 = = 1,6

P 2 __ P 1

10 ____ 5 = = 2,0

With pressure increase ratio from 1,6 to 2,0, charge time of 3,5 – 1,1 = 2,4 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:

With pressure increase ratio from 1,6 to 2,0, charge time of 4,3 – 1,3 = 3,2 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:

100 __ 10

100 __ 10

V __ 10

V __ 10

T = t x

= 2,4 x

= 24 s

T = t x

= 3,2 x

= 32 s

4.50.7