GENERAL CATALOGUE API
Pressure boosters
Charge features
Ratio: 2:1
Type: MLTR2A09
Type: MLTR2B09
Type: MLTR3A09 MLTP3A09
60
400
12 11 10
50
300
9 8 7 6 5 4 3 2 1 0 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0
40
30
200
20
100
Charging time* t (s)
Charging time* t (s)
Charging time* t (s)
10
0 1,0 1,2 1,4 1,6 1,8 2,0
0 1,0 2,0 3,0 2,0
Pressure increase ratio P 2 /P 1
Pressure increase ratio P 2 /P 1
Pressure increase ratio P 2 /P 1
*Note: for 10 L Required time to charge pressure in the air- reservoir from 10 to 15 bar at 5 bar supply pressure:
*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:
*Note: for 10 L Required time to charge pressure in the air-reservoir from 7 bar to 9,5 bar at 5 bar supply pressure:
P 2 __ P 1
7 __ 5 = = 1,4
P 2 __ P 1
9,5 ____ 5 = = 1,9
P 2 __ P 1
10 __ 5 = = 2,0
P 2 __ P 1
15 ____ 5 = = 3,0
P 2 __ P 1
8 __ 5 = = 1,6
P 2 __ P 1
10 ____ 5 = = 2,0
With pressure increase ratio from 2,0 to 3,0, charge time of 147 – 58 = 89 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:
With pressure increase ratio from 1,6 to 2,0, charge time of 11,5 – 3,8 = 7,7 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:
With pressure increase ratio from 1,4 to 1,9, charge time of 23 – 6 = 17 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:
10 __ 10
10 __ 10
100 __ 10
V __ 10
V __ 10
V __ 10
T = t x
= 17 x
= 17 s
T = t x
= 89 x
= 89 s
T = t x
= 7,7 x
= 17 s
Type: MLTR4A09 MLTP4A09
Type: MLTR4A16
5
5
4
4
3
3
2
2
1 Charging time* t (s)
1 Charging time* t (s)
0 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0
0
1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2,0
Pressure increase ratio P 2 /P 1
Pressure increase ratio P 2 /P 1
*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:
*Note: for 10 L Required time to charge pressure in the air-reservoir from 8 bar to 10 bar at 5 bar supply pressure:
4 - ACCESSORIES
P 2 __ P 1
8 __ 5 = = 1,6
P 2 __ P 1
10 ____ 5 = = 2,0
P 2 __ P 1
8 __ 5 = = 1,6
P 2 __ P 1
10 ____ 5 = = 2,0
With pressure increase ratio from 1,6 to 2,0, charge time of 3,5 – 1,1 = 2,4 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:
With pressure increase ratio from 1,6 to 2,0, charge time of 4,3 – 1,3 = 3,2 s (t) is given by the table above. Therefore, the charge time (T) for 10 L air- reservoir is:
100 __ 10
100 __ 10
V __ 10
V __ 10
T = t x
= 2,4 x
= 24 s
T = t x
= 3,2 x
= 32 s
4.50.7