GENERAL CATALOGUE API
Valve terminals series A5 Selection, configuration and code key
Code key
Series
Size
Communication Positions
Piloting (1)
Valve type
Valve sequence (2)
/
Plugs (2)
/
Diaphragms (2)
A5
14
07
09
E
B
1C2D4S /
2T0409 /
AR0405
A5
10 = 10 mm
04 = 4 positions
E = External
B = Sub-bases valve
T = Plug
L (3) = Semi in-line valve
14 = 14 mm
05 = 5 positions
I = Internal
06 = 6 positions
01 = Fieldbus ProfiNET ®
07 = 7 positions
02 = Fieldbus EtherCAT ®
C = 5/3 closed centres
A = Feeding diaphragm
08 = 8 positions
03 = Fieldbus EtherNET/IP ®
E = 5/3 open centres
R = Exhaust diaphragm
09 = 9 positions
04 = Fieldbus CC-Link IE ™ Field Basic
P = 5/3 pressurized centres
10 = 10 positions
09 = Fieldbus ProfiBUS ®
D = 5/2 solenoid/solenoid
12 = 12 positions
05 = Sub-D 25 poles
F = 2-3/2 N.C.
14 = 14 positions
2 - VALVES
06 = IO-Link ® (up to 8 managed valves)
G = 2-3/2 N.O.
16 = 16 positions
07 = IO-Link ® (up to 16 managed valves)
H = 2-3/2 N.C.-N.O.
20 = 20 positions
08 = IO-Link ® (up to 24 managed valves)
S = 5/2 solenoid/spring
24 = 24 positions
Important note The desired valves has to be inserted in the code key as per the sequence indicated in the table: first 5/3, then 5/2 sol./sol., then 2-3/2, finally 5/2 sol./spring.
How to order (4)
Series
Size
Communication Positions
Piloting
Valve type
Valve sequence
Plugs
Diaphragms
A5
14
07
09
E
B
1C2D4S /
2T0409 /
AR0405
Notes
For standard materials see from page 2.70.7 For selection and configuration of the valve island, see from page 2.70.4 (1) For further information on internal or external piloting, see page 2.70.6 (2) For further information on valves sequence and position, on plugs and diaphragms sequence and position, see from page 2.70.4 (3) For semi in-line valves, please contact the sales department.
(4) Order example for 9 position sub-base, size 14mm, external piloting, IO-Link ® 16 communication interface and the following solenoid valves assembled starting from the feeding/ communication module: one element with 5/3 closed centres function, two elements with 5/2 solenoid/solenoid function, one plug for unused position, diafraghm for separated feeding and diaphragms for separated exhausts, four elements with 5/2 solenoid/spring function and one plug for unused position.
2.70.3