GENERAL CATALOGUE API

Valve terminals series A5 Selection, configuration and code key

Code key

Series

Size

Communication Positions

Piloting (1)

Valve type

Valve sequence (2)

/

Plugs (2)

/

Diaphragms (2)

A5

14

07

09

E

B

1C2D4S /

2T0409 /

AR0405

A5

10 = 10 mm

04 = 4 positions

E = External

B = Sub-bases valve

T = Plug

L (3) = Semi in-line valve

14 = 14 mm

05 = 5 positions

I = Internal

06 = 6 positions

01 = Fieldbus ProfiNET ®

07 = 7 positions

02 = Fieldbus EtherCAT ®

C = 5/3 closed centres

A = Feeding diaphragm

08 = 8 positions

03 = Fieldbus EtherNET/IP ®

E = 5/3 open centres

R = Exhaust diaphragm

09 = 9 positions

04 = Fieldbus CC-Link IE ™ Field Basic

P = 5/3 pressurized centres

10 = 10 positions

09 = Fieldbus ProfiBUS ®

D = 5/2 solenoid/solenoid

12 = 12 positions

05 = Sub-D 25 poles

F = 2-3/2 N.C.

14 = 14 positions

2 - VALVES

06 = IO-Link ® (up to 8 managed valves)

G = 2-3/2 N.O.

16 = 16 positions

07 = IO-Link ® (up to 16 managed valves)

H = 2-3/2 N.C.-N.O.

20 = 20 positions

08 = IO-Link ® (up to 24 managed valves)

S = 5/2 solenoid/spring

24 = 24 positions

Important note The desired valves has to be inserted in the code key as per the sequence indicated in the table: first 5/3, then 5/2 sol./sol., then 2-3/2, finally 5/2 sol./spring.

How to order (4)

Series

Size

Communication Positions

Piloting

Valve type

Valve sequence

Plugs

Diaphragms

A5

14

07

09

E

B

1C2D4S /

2T0409 /

AR0405

Notes

For standard materials see from page 2.70.7 For selection and configuration of the valve island, see from page 2.70.4 (1) For further information on internal or external piloting, see page 2.70.6 (2) For further information on valves sequence and position, on plugs and diaphragms sequence and position, see from page 2.70.4 (3) For semi in-line valves, please contact the sales department.

(4) Order example for 9 position sub-base, size 14mm, external piloting, IO-Link ® 16 communication interface and the following solenoid valves assembled starting from the feeding/ communication module: one element with 5/3 closed centres function, two elements with 5/2 solenoid/solenoid function, one plug for unused position, diafraghm for separated feeding and diaphragms for separated exhausts, four elements with 5/2 solenoid/spring function and one plug for unused position.

2.70.3

Made with FlippingBook Online newsletter creator