GENERAL CATALOGUE API

Valve terminals series A5 Selection, configuration and code key

Elements sequence example

6

7

8

3

2

9

1

10

5

4

Pos.1 Pos.2 Pos.3 Pos.4 Pos.5 Pos.6 Pos.7 Pos.8 Pos.9

1

2

3

4

5

6

7

8

9

10

2 - VALVES

A5

14

07

09

E

B

1 C

2 D

4 S

/

2 T 04 09

/

A R 0405

N.

Sequence type

Sequence

Description

Terminal size Module type Position number Piloting type

1

Size 14 mm

14

Feeding/communication module IO-Link ® up to 16 managed valves

2

07

9 positions on sub-base

Valve terminal features

3

09

External piloting

4

E

Valve type

Sub-base valve

5

B

(Table1)

Elements number

Valve function

C = 5/3 closed centres E = 5/3 open centres

1 valve 5/3 closed centres

6

1 C

Sequence at set positions (valves) The desired valves has to be inserted in the code key as per the sequence indicated in the table1: first 5/3, then 5/2 sol./sol., then 2-3/2, finally 5/2 sol./spring.

P = 5/3 pressurized centres D = 5/2 solenoid/solenoid F = 2-3/2 N.C. G = 2-3/2 N.O. H = 2-3/2 N.C.-N.O. S = 5/2 solenoid/spring

Elements number

Valve function

7

2 valves 5/2 solenoid/solenoid

2 D

Elements number

Valve function

4 valves 5/2 solenoid/spring

8

4 S

Elements type

Positionable sequence (plugs)

2 nd element position

Elements number

2 plugs in position 04 and 09

9

2 T 04 09

T = Plug A = Feeding diaphragm R = Exhaust diaphragm

1 st element position

Positionable sequence (diaphragms)

Diaphragms for separated feeding and exhaust positioned between 04 and 05

Elements type

Elements position

10

A R 0405

2.70.5