GENERAL CATALOGUE API

Interfaces for valve terminals series A5 Fieldbus

Main features

Version

Code

Item Symbol

Fieldbus interface with ProfiBUS ® protocol

036205

A509

Technical data

Item

A509

Communication protocol

ProfiBUS ®

Maximum managed valves

24 solenoid valves (also with double electric pilot)

Temperature range

-5°C ÷ +60°C

2 - VALVOLEES

Voltage

24 VDC

Electrical consumption

1,2 W

Power supply port

M12 Male 4 pin connector, A-coded (for configuration see table below)

Communication port input / output

M12 Male 4 pin connector, D-coded / M12 Female 4 pin connector, D-coded (for configuration see table below)

Power supply cable* M12 Female cable type CAVFBFD Communication cable* input / output M12 Female cable type CAVPBFD / M12 Male cable type CAVFBMD, CAVFBMM, CAVFBMR Control On integrated dial (see table below) Control indicator LED (see table below)

*Cables to be ordered separately, see from page 2.75.40

Fieldbus module

N.

Description

Function

1

2

1

Control dial

Allows to set the IP address and valve coils

2

Control indicator

Indicates the status and operation of functions via LEDs

3

Communication (output)

Output communication port type M12 Female 4-pin, D-coded

4

Communication (input)

Input communication port type M12 Male 4-pin, D-coded

5

3

4

5

Power supply

Power supply input port type M12 Male 4-pin, A-coded

Power supply configuration

Communication configuration (output)

Communication configuration (input)

Pin Function

Pin Funzione

Pin Funzione

1 VP (+5V) 2 RxD/TxD-N A line 3 DGND- 4 RxD/TxD-N B line

1 VP (+5V) 2 RxD/TxD-N A line 3 DGND- 4 RxD/TxD-N B line

1 UA Actuator power supply 2 GND Actuator power supply 3 US Bus power supply 4 GND Bus power supply

2 1

1 2

2

1

Data transfer (-) Data receiving (-)

Trasmissione dati (-) Ricezione dati (-)

4

3

3

4

3

4

Data transfer (+) Data receiving (+)

Trasmissione dati (+) Ricezione dati (+)

2.73.15