GENERAL CATALOGUE API
Valve terminals series A5 complete and assembled With Fieldbus interface
Main features
Version
Code
Item Symbol
Valve terminal size 10 mm with Fieldbus interface ProfiNET ® protocol Valve terminal size 14 mm with Fieldbus interface ProfiNET ® protocol Valve terminal size 10 mm with Fieldbus interface EtherCAT ® protocol Valve terminal size 14 mm with Fieldbus interface EtherCAT ® protocol Valve terminal size 10 mm with Fieldbus interface EtherNET/IP ® protocol Valve terminal size 14 mm with Fieldbus interface EtherNET/IP ® protocol Valve terminal size 10 mm with Fieldbus interface CC-Link IE ™ Field Basic protocol Valve terminal size 14 mm with Fieldbus interface CC-Link IE ™ Field Basic protocol Valve terminal size 10 mm with Fieldbus interface ProfiBUS ® protocol Valve terminal size 14 mm with Fieldbus interface ProfiBUS ® protocol
*
A51001..
*
A51401..
*
A51002..
*
A51402..
*
A51003..
*
A51403..
*
A51004..
*
A51404..
*
A51009..
*
A51409..
*For the full article and code please see page 2.70.3
Technical data
2 - VALVOLEES
Item
A51001..
A51002..
A51003..
A51004..
A51009..
A51401..
A51402..
A51403..
A51404..
A51409..
Size
10 mm
14 mm
EtherNET/IP ® CC-Link IE ™
CC-Link IE ™ Field Basic ProfiBUS ®
Communication protocol
ProfiNET ®
EtherCAT ®
ProfiNET ®
EtherCAT ®
EtherNET/IP ®
Field Basic ProfiBUS ®
Interface module features Positions on sub-base
See page 2.73.10
p. 2.73.15 See page 2.73.10
p. 2.73.15
4 ÷ 24 (4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 20, 24)
Fluid
Compressed air with or without lubrication. Lubrication, if started, must be continued.
Minimum 2 bar (5/2) - 3 bar (5/3) - 2,5 bar (2-3/2) Maximum 8 bar
Pressure range
Temperature range
-5°C ÷ +60°C
Flow at 6 bar with ∆P 1bar
300 l/min
600 l/min
Sub-base air supply Sub-base exhausts
G 1/4" G 1/4"
Connection for external piloting (1)
M5 M7
Sub-base outlets
G 1/8"
Voltage
24 VDC
Electrical consumption
1,2 W
Maximum number of valves (2) Internal data transmission
24 (also with double electric pilot)
With integrated PCB "Push" and bistable
Manual override
Notes
For possible configurations of the valve terminal see from page 2.70.3; The configuration does not include fittings, exhaust silencers and connection cables for the communication interface, are to be ordered separately. For inlet, exhaust and exthernal piloting fittings see from page 4.3.1; For silencers see from page 4.150.1; For diaphragms, plugs and outlet fittings, see from page 2.75.20; For communication cables see from page 2.75.40 (1) In case of external pilot configuration. (2) Depending on the number of positions on the sub-base. For valves features, see from page 2.71.1; For sub-bases features, see from page 2.72.1
2.74.20