GENERAL CATALOGUE API

Valve terminals series A5 complete and assembled With Fieldbus interface

Main features

Version

Code

Item Symbol

Valve terminal size 10 mm with Fieldbus interface ProfiNET ® protocol Valve terminal size 14 mm with Fieldbus interface ProfiNET ® protocol Valve terminal size 10 mm with Fieldbus interface EtherCAT ® protocol Valve terminal size 14 mm with Fieldbus interface EtherCAT ® protocol Valve terminal size 10 mm with Fieldbus interface EtherNET/IP ® protocol Valve terminal size 14 mm with Fieldbus interface EtherNET/IP ® protocol Valve terminal size 10 mm with Fieldbus interface CC-Link IE ™ Field Basic protocol Valve terminal size 14 mm with Fieldbus interface CC-Link IE ™ Field Basic protocol Valve terminal size 10 mm with Fieldbus interface ProfiBUS ® protocol Valve terminal size 14 mm with Fieldbus interface ProfiBUS ® protocol

*

A51001..

*

A51401..

*

A51002..

*

A51402..

*

A51003..

*

A51403..

*

A51004..

*

A51404..

*

A51009..

*

A51409..

*For the full article and code please see page 2.70.3

Technical data

2 - VALVOLEES

Item

A51001..

A51002..

A51003..

A51004..

A51009..

A51401..

A51402..

A51403..

A51404..

A51409..

Size

10 mm

14 mm

EtherNET/IP ® CC-Link IE ™

CC-Link IE ™ Field Basic ProfiBUS ®

Communication protocol

ProfiNET ®

EtherCAT ®

ProfiNET ®

EtherCAT ®

EtherNET/IP ®

Field Basic ProfiBUS ®

Interface module features Positions on sub-base

See page 2.73.10

p. 2.73.15 See page 2.73.10

p. 2.73.15

4 ÷ 24 (4, 5, 6, 7, 8, 9, 10, 12, 14, 16, 20, 24)

Fluid

Compressed air with or without lubrication. Lubrication, if started, must be continued.

Minimum 2 bar (5/2) - 3 bar (5/3) - 2,5 bar (2-3/2) Maximum 8 bar

Pressure range

Temperature range

-5°C ÷ +60°C

Flow at 6 bar with ∆P 1bar

300 l/min

600 l/min

Sub-base air supply Sub-base exhausts

G 1/4" G 1/4"

Connection for external piloting (1)

M5 M7

Sub-base outlets

G 1/8"

Voltage

24 VDC

Electrical consumption

1,2 W

Maximum number of valves (2) Internal data transmission

24 (also with double electric pilot)

With integrated PCB "Push" and bistable

Manual override

Notes

For possible configurations of the valve terminal see from page 2.70.3; The configuration does not include fittings, exhaust silencers and connection cables for the communication interface, are to be ordered separately. For inlet, exhaust and exthernal piloting fittings see from page 4.3.1; For silencers see from page 4.150.1; For diaphragms, plugs and outlet fittings, see from page 2.75.20; For communication cables see from page 2.75.40 (1) In case of external pilot configuration. (2) Depending on the number of positions on the sub-base. For valves features, see from page 2.71.1; For sub-bases features, see from page 2.72.1

2.74.20

Made with FlippingBook Online newsletter creator