GENERAL CATALOGUE API
Valves ISO 5599/1 air operated ISO1, 5/2 pilot/pilot
Main features
Version
Code
Item
Symbol
4 2
14
12
5/2 pilot/pilot
032001
ISO1P51
5 31
4 2
14
12
5/2 pilot/pilot differential
032002
ISO1P52
5 31
Technical data
Version
5/2 pilot/pilot
5/2 pilot/pilot differential
Code
032001
032002
2 - VALVES
Item
ISO1P51
ISO1P52
Size
ISO1
Fluid
Compressed air with or without lubrication. Lubrication, if started, must be continued.
Pressure range
1 ÷ 10 bar
Temperature range
-10°C ÷ +60°C
Orifice Ø
8,5 mm
Flow at 6 bar with Δ P 1 bar
1.100 Nl/min.
Mounting
In every position
2.101.50