GENERAL CATALOGUE API

Solenoid operated valves, ATEX coils and connectors Complete solenoid operated valves type XC, explosion proof coil Ex d

Code key solenoid valves ATEX complete with coils and connectors (serie A1 e A1N)

Series

Actuation

Size

Function

ATEX coil

Coil voltage

Option

A1

E

2

50

XA

C

See table on page 2.322.1

XC =

A1 = In line

E = Electric

2 = 1/4"

30 = 3/2 N. C.

II 2G Ex db IIC T6 Gb

A1N (1) = Namur

31 = 3/2 N. A.

32 = 3/2 Sol./Sol.

50 = 5/2 Sol./Spring

51 = 5/2 Sol./Sol.

52 = 5/2 Sol./Sol. differential

2 - VALVES

70 = 5/3 C.C.

71 = 5/3 O.C.

BT = Low temperatures seals

72 = 5/3 P.C.

How to order

Notes

Options in the same grid are alternative to each others. For features and standard materials of the valve body, see from page 2.20.7 (series A1) and from page 2.44.3 (series A1N). For features and standard materials of coils/connectors see page 2.320.3. (1) Namur valves (series A1N) is available only in functions 3/2 N.C. (30), 3/2 sol./sol. (32), 5/2 sol./spring (50), 5/2 sol./sol. (51), 5/3 C.C. (70), 5/3 C.A. (71) and 5/3 C.P. (72). For further information on the ATEX 2014/34/EU Directive, on classifications and protections, see from page III.1

Series Actuation Size Function

Coil

Voltage

A1

E

2

50

XC C

2.322.2